GEZE TS4000 door closer on a 1400mm wide door

June 24, 2014 by · Comments Off on GEZE TS4000 door closer on a 1400mm wide door 

FERRY DOOR 246

The GEZE TS4000 door closer can be used on doors up to 1400mm wide, as seen above on this Stenaline Ferry for the giant double doors on their fashion shop entrance.  TS4000 door closers come with adjustable closing force, optical strength indicator, back check, latching action and all valve adjustments on the front of the mechanism.  On these doors the power would be set up to EN 6, and they are being used in conjunction with foot operated door holders while the store is open.  Can be used for right and left hand doors in figure 1, 61 & 66 applications.

Coroner rules on safety failures including the fire door closer as cause of tragic death

May 8, 2014 by · Comments Off on Coroner rules on safety failures including the fire door closer as cause of tragic death 

sophie rosser
23 year old Architect Sophie Rosser died from burns in the Royal London Hospital after entering a blazing block of flats in an ill-fated attempt to save her boyfriend, who she feared was trapped inside. Coroner Mary Hassell criticised a catalogue of fire safety failures at the apartment block, but ruled the 23-year-old’s death was an accident. The fatal blaze was sparked by a damp towel being left on a wall light in a fourth floor flat at Meridian Place on the Isle of Dogs, east London, in the early hours of August 26 2012. The coroner hit out at a string of failures in the fire safety of the block of flats – which she said was partly to blame for the tragedy. She said the fire quickly spread because the apartment’s self-closing fire door was damaged and got stuck on the floor, and that Miss Rosser’s death could have been avoided if the self-closing fire door was functioning as it should have been. “The fire brigade came quickly. The fire door was a good one and it would have kept the fire back.” She added: “The one thing that would have made the world of difference, other than the fire not being started in the first place, is if the door to flat 101 (where the fire broke out) had been closed.” Doorstuff technical department wonders if rather than the fire door closer, the fire door hinges had failed in this case, causing the door to drop and therefore catch on the floor. Whatever had happened, this terrible event underlines the importance of maintaining fire doors and their associated hardware.

Q: Could you provide adjustment instructions for your medium/heavy duty fire door closure. Unit is 9″+. Not sure if it’s working or not?

August 29, 2011 by · Comments Off on Q: Could you provide adjustment instructions for your medium/heavy duty fire door closure. Unit is 9″+. Not sure if it’s working or not? 

A: We think you may be describing a Geze TS2000 door closer, the body of which is 226mm long (9″ = 229mm).  You can see some fitting and adjusting information on the pdfs at the bottom of the web page .  If you’re still struggling, do get in touch on the phone and we’ll help if we can.here