Panic and Emergency Exit Hardware Classification

Heavy_Duty

Classification Coding System for Panic and Emergency Exit Hardware

Under both these two standards each product is tested and classified accordingly to show its compliance by the identification of a 10-digit code that is visible on the product and fitting instructions.  Each digit represents a category and how it is measured against the standard to which it was tested.

Classification Coding System for Panic and Emergency Exit Hardware

Digit 1 - Category of Use
Only one category is identified
3 = high frequency of use where there is little incentive to exercise care, i.e.
where there is a chance of an accident occurring and misuse.
Example: Doors to shops, hospitals, schools and other buildings which provide
access to designated areas and which are used by the public and others
frequently carrying or propelling bulky objects.

Digit 2 - Durability
6 = tested up to 100,000 cycles
7 = tested up to 200,000 cycles

Digit 3 - Door Mass
5 = for doors up to 100kg
6 = for doors up to 200kg
7 = for doors over 200kg

Digit 4 - Suitability for use on fire/smoke doors
0 = not approved for use on fire/smoke door assemblies
A = suitable for use on smoke door assemblies
B = Suitable for use on fire and smoke door assemblies based on a test in
accordance with EN1634-1

Digit 5 - Safety
Only the top grade is allowed on panic and emergency exit hardware
1 = safety

Digit 6 - Corrosion Resistance to EN 1670
3 = high resistance
4 = very high resistance

Digit 7 - Security for Products
EN 1125
2 = 1,000 N - this is the grade allowed under EN 1125
EN 179
2 = 1,000N / 3 = 2,000N / 4 = 3,000N / 5 = 5,000N
These four grades are used to allow the opportunity of greater security
because these devices are subject to testing with doors under a greater
pressure.

Digit 8 - Projection of Device
1 = large projection (projection of 150mm from the face of the door)
2 = standard projection (projection of 100mm from the face of the door)

Digit 9 - Type of Device
EN 179
A = emergency device using a lever handle
B = emergency device using a push pad
EN 1125
A = panic device using a push bar
B = panic device using a touch bar

Digit 10 - Door Application
EN 179
A = outwardly opening single exit door, double exit door: active or inactive leaf
B = outwardly opening single exit door only
C = outwardly opening double exit door: inactive leaf only
D = inwardly opening single exit door only
EN 1125
A = single door, double door: active or inactive leaf
B = single door only
C = double door: inactive leaf only