Posts by Door Admin
I want my fire door to hold open at 90° until someone pulls it, then the door closer kicks in and closes it as normal. What product will do this?
Under Fire Regulations fire doors must not be held or propped open. Without using an electromagnetic hold open door closer wired into the fire alarm, the only suggestion is to use a delayed action door closer, which can hold the door open for up to 90 seconds, then closing as normal. I recommend the Geze TS4000S…
Read MoreQ: Choosing ironmongery for four final fire exit doors and frames which will experience heavy traffic, and need to be secure (would prefer not to have a panic bar), can you recommend a handle arrangement, perhaps with a thumblock on the inside, that would be suitable for these circumstances?
A: For the arrangement you describe we would suggest using escape sashlocks – these have euro cylinder thumb turn locks (i.e. you can have any kind of high security, master keyed, anti pick, anti bump etc euro profile cylinder) but use a split spindle so from the inside the handle will ALWAYS over-ride the lock…
Read MoreQ: I am looking for a door opening rate, and travel extent, restrainer to limit the RATE at which the wind could snatch an outward opening patio door. Closing force should be low or zero. Do any door closers do this? Could any be mounted in reverse to achieve this?
A: What you’re looking for is a “back check” door closer”. This feature dampens or brakes the opening, as well as controlling the close as a normal door closer. You can look at the TS2000NVBC or the TS4000 which comes with back check as a standard feature. The TS4000 can be adjusted down to closing…
Read MoreQ: Recommend a product for fire escape doors with door closers – when the doors slam shut they LOCK; so is there a mechanism which allows us to keep the door bolts UNLOCKED until we want to LOCK the doors?
A: Yes, such a mechanism exists and is called a dogging device(opens in new tab), it allows the bolts to be withheld in the retracted position ensuring the automatic top trip catch or Pullman latch do not engage when the door is closed, enabling the door to be opened freely from both sides. It’s disengageable. It…
Read MoreTenants told not to tamper with fire doors following blaze
TENANTS living in the Lord Street flats in Douglas, Isle of Man, have been urged not to wedge open or tamper with fire doors following a fire earlier this week. Douglas Borough Council has issued the warning after four people were taken to hospital following a fire in flat 55 of the Murray’s House block…
Read MoreQ: Recommend a door closer for an arched door?
A: For a heavy arched door you’ll need to use EITHER:- a concealed jamb door closer such as the AA145 which may be powerful enough, but check. OR:- a floor spring door closer, sunk into the floor at the hinge side of the door, check out the product pages here on the website for more…
Read MoreQ: Can a Hideaway pocket door kit be fitted from one side of a plasterboard stud partition?
A: Yes, it is possible to fit a Hideaway pocket door system from one side only, we are aware of customers who have done this successfully, although your finished wall thickness will be slightly more than the 115 – 120mm shown in the specifications. How easy the project is may depend on what you find…
Read MoreQ: Could you provide adjustment instructions for your medium/heavy duty fire door closure. Unit is 9″+. Not sure if it’s working or not?
A: We think you may be describing a Geze TS2000 door closer(opens in new tab), the body of which is 226mm long (9″ = 229mm). You can see some fitting and adjusting information on the pdfs at the bottom of the web page or here. If you’re still struggling, do get in touch on the…
Read MoreMedia & Press
Doorstuff welcomes technical enquiries from researchers, production companies and the media about meeting fire, building & disability regulations with respect to door furniture. We are happy to give expert comment where appropriate and also to give background briefing for members of the press who need information on the implications of the regulations and developments in the guidelines. We…
Read MoreQ: What part of a door closer is the mounting plate?
A: The mounting plate, for clarification, is a thin metal plate the same size as the body of the closer. It is good to use one for example on a uPVC door because it has lots of pre-drilled holes to enable a really firm positioning before attaching the door closer body to the plate through…
Read MoreQ: Recommend a door closer suitable for fitting to a PVC Front door? Fed up with kids slamming the door every time. Door opens inwards.
A: When choosing a door closer for a uPVC door, similar criteria apply to when choosing for a timber door; how wide is the door? What is its function? etc. We suggest selecting a door closer which has an optional mounting plate and bolting through the door and the frame if possible. Minimum specification a…
Read MoreQ: Is it possible to cut the Jason track myself to suit a particular size door?
A: Yes, the Jason sliding door tracks are easy to cut down with a junior hacksaw.
Read MoreQ: What is passage mode on the Exidor digilock?
A: Passage mode is an optional feature of the Exidor CL2(opens in new tab) which, when simply set with a screwdriver, allows free access through the door using just the handle, i.e. entry WITHOUT code. An example of this being used is in a primary school when code entry(opens in new tab) is used during…
Read MoreNo Credit / Debit card charges
As this is a hot topic today, Doorstuff are pleased to reassure that we do not make any charge for using credit or debit cards (or any other payment method).
Read MoreQ: Can I put panic hardware on an external gate?
A: Yes, you can. You might consider going for the Exidor 296 push bar or an Exidor 297 push pad. It may be necessary to shield the panic bar from the outside to ensure security (depending upon the design of the gate). You may expect a slightly shortened life expectancy for the units due to…
Read MoreWhat is meant by “bolt through” door handles?
Bolt through door handles are the best way to ensure the handles don’t get pulled off in high use settings like schools & offices. Usually only available on round roses, the bolts go straight through the door AND the lock case or the latch. It’s essential to check the locks and latches are suitable for…
Read MoreQ: What does “back check” mean on heavy duty door closers?
A: “Back Check” stops the door slamming open; two examples:- on an external door in a windy location back check prevents the wind from “picking up” and opening the door (which might damage the frame at the hinges); or when there is a wall at 90° from the door back check stops damage to the…
Read MoreQ: I have an Arrow door closer and it seems to have stopped working. i.e the door now slams shut. Could you call me to advise how to fix?
A: Once door closers have lost hydraulic pressure, they slam the door and unfortunately can’t be fixed. Best course of action is replace with a new door closer.
Read MoreDo your pocket doors provide any sound insulation between the adjacent rooms (i.e. in the partition itself as well as where the 2 doors meet each other)?
There is no sound insulation material supplied with either pocket door systems we supply (the Hideaway and the iMpero deluxe), but it would be possible to add your own brush strip to the top and bottom of the doors, although this wouldn’t look right on the leading edges. The wall cavity is going to be…
Read MoreI have a fire door between my utility and garage. (W27″ X H78″ X D44mm), it is currently fitted with an undamped chain closer, which frequently results in the door slamming shut with some force…
…I would like to remove the chain closer and replace it with an overhead closer with speed and latching control. Can you recommend a suitable closer from the Geze range? At 27″ wide, your door is on the narrow side, so we’d recommend a door closer which has some adjustability on the power, because you…
Read MoreWhich door closers – our doors are hardwood 45mm x 840mm x 1981mm, we are not sure if Geze TS1000 will be sufficient or if we will need Geze TS1500. Please could you advise?
The TS1000 door closers are perfectly adequate to cope with fire rated doors up to 900mm wide. Geze TS1500‘s are able to cope with a wider range of door sizes, and are a little more attractive to look at. The Eurospec F2003 is another suitable choice, as is the Briton 121.CE.
Read More