There are two power settings and changing them is all about the position of the arm. The part of the arm which fixes to the frame (in figure 1, standard, fitting) is called the shoe. If the “toe” of the shoe is pointing towards the hinge side of the frame, the power is set on power 3 to EN1154 (~WEAK),…
Door assemblies are still legal after 1 July 2013. And they will stay legal for the foreseeable future. Door assemblies are NOT doorsets – so CE marking doesn’t apply to them. You can’t tell the difference between doorsets and door assemblies just by looking at them. It’s how they’re supplied that matters. If it all…
Our last date for dispatch this year is Thursday 19th December and our sales office closes at 4pm on Friday 20th December. We will begin dispatching again on 2nd and 3rd January 2014, but our sales office and phone lines do not re-open until Monday 6th January. If you need to contact us about an order,…
All mandatory signs for fire check doors needs to be white writing on a circular blue background to be in accordance with BS5499-1:2002. (This is not to be confused with fire escape doors and the associated green man running signs.) Approved wording is “Fire Door Keep Shut”, “Fire Door Keep Locked” and “Automatic Fire Door Keep…
The hinge on the left is a stainless steel 4″ ball bearing butt hinge spotted on a fire door in the gents’ toilet of a busy Exeter department store. The hinge on the right is a new stainless steel 4″ ball bearing butt hinge, pictured for comparison purposes. The top bearing has collapsed, its ball bearings have…
We looked under the hood (or slide plate to give it the correct name) of a GEZE TS3000V door closer to photograph the fitting holes and adjustment screws, here’s what you’ll find there. Its very similar to the TS2000NVBC but they are not interchangeable with each others arms & guide rails because the spindles are…
The GEZE TS3000V guide rail door closer combines the best features of GEZE’s range for mounting on fire and smoke protection doors up to 1100mm wide; The guide rail makes for a smoother action than “scissor arm” (or “link arm”) door closers, making it a good choice when meeting DDA (The Equalities Act) recommendations. – Economical…
Recently asked to give some broad guidance on maximum allowable door sizes using the Geze TS500 NV floor spring for a set of double timber doors (44mm thick solid core) 1050mm wide, an opening height of 3.2m, where the door height could be maximised without an obtrusive overpanel. Was there a weight rule of thumb for…
It’s the versatility and reliability, its hard wearing but gentle action we love. While ticking all the regulatory boxes of fire regs, DDA, CE marking etc, it is almost always the best door closer in so many ways. Let me tell you its story; GEZE designed the TS4000 model with power adjustability, back check as…
A hold open and free swing door closers which can be fitted on either side of the door in Fig 1 or Fig 66 all in one box. This British made door closer gives good reliability with the flexibility that one unit covers both eventualities. In stock with quantity discounts.
If the doors are going to get a lot of traffic, we’d recommend a GEZE TS4000, or at least a GEZE TS2000 NVBC (a door of 1100mm wide will require at least power size 4) but if there are any draught seals on the doors, it may need to be a higher power size. If…
We recommend looking at a Geze TS4000 tandem (power 7-13), or a TS4000 power 5-7, and caution that this door will be very heavy to open. You can buy them online here, follow the links in the text.
I think you may be right that floor spring door closers (e.g. Geze TS500 NV) would probably be the best option for your double action doors. The only other possibility is a concealed closer (e.g. The Geze Boxer) fitted into the head of the door, but you’d need to check there was enough thickness &…
There are two ways of tackling this, depending on your budget. The “deluxe” solution would be to use an electro-magnetic door closer (the Geze TS4000 EFS) with a PSU, the current to which would be switched ON in summer, so the door can free swing. In winter you switch the power OFF and the door…
Yes, we supply a range of Briton door closers including the Briton 2000 range. The range includes the heavy duty guide rail Briton 2700, the UK’s most popular door closer the Briton 2003, and the great value Briton 121CE.
General door closers usually come in fixed power size 3, which ensures they are strong enough to meet fire regulations for closing large fire doors up to about 900mm wide. If this is the type you’ve previously fitted, then the fixed power size is your problem – this makes them too strong for children and…
A TS1500 is a good choice and can be dressed up with a matching cover & arm in polished brass for example. Having a close look at the photo, we would like to suggest perhaps fitting the closer in the “Figure 66” position on the other side of the door. This is because there is…
An overhead hydraulic door closer would be a good solution for your slamming problem. For a large fire door (and width is the most important dimension to consider) you might go for a medium to heavy duty door closer(opens in new tab) like the GEZE TS4000 or the TS2000NV. For a narrower door; the domestic…
The door closer we would recommend for your scenario would be the Geze TS4000. It is fully adjustable in power size, so you’ll be able to set it up to operate exactly as you want it, and it’s easy to do – so you can personally set it to high power during windy spells and reduce the power…