Q: I have a door that is a glass panel at the top. The wood above the glass to the door stop is approx 73mm. The door opens outwards. The door is on a warehouse and is used quite a lot by the public. I have brought 2 closers from my local DIY centre but they do not fit due to the narrow bit at the top. What do you recommend?

By Door Admin / 22 December 2011

A: There are two possible solutions; Option 1.) Using a door closer with a Drop Plate, e.g. the Geze TS2000NVBC (which is a really good mid-range, mid-price model) – the drop plate (shown above) allows the body to be set lower than the fixing positions, over the glass in this case, and it is an extra £18.00…

I want my fire door to hold open at 90° until someone pulls it, then the door closer kicks in and closes it as normal. What product will do this?

By Door Admin / 22 October 2011

Under Fire Regulations fire doors must not be held or propped open.  Without using an electromagnetic hold open door closer wired into the fire alarm, the only suggestion is to use a delayed action door closer, which can hold the door open for up to 90 seconds, then closing as normal.  I recommend the Geze TS4000S…

Q: I am looking for a door opening rate, and travel extent, restrainer to limit the RATE at which the wind could snatch an outward opening patio door. Closing force should be low or zero. Do any door closers do this? Could any be mounted in reverse to achieve this?

By Door Admin / 15 October 2011

A: What you’re looking for is a “back check” door closer”.  This feature dampens or brakes the opening, as well as controlling the close as a normal door closer.  You can look at the TS2000NVBC or the TS4000 which comes with back check as a standard feature. The TS4000 can be adjusted down to closing…

Q: Recommend a door closer for an arched door?

By Door Admin / 29 August 2011

A: For a heavy arched door you’ll need to use EITHER:- a concealed jamb door closer such as the AA145 which may be powerful enough, but check.   OR:- a floor spring door closer, sunk into the floor at the hinge side of the door, check out the product pages here on the website for more…

Q: Could you provide adjustment instructions for your medium/heavy duty fire door closure. Unit is 9″+. Not sure if it’s working or not?

By Door Admin / 29 August 2011

A: We think you may be describing a Geze TS2000 door closer(opens in new tab), the body of which is 226mm long (9″ = 229mm).  You can see some fitting and adjusting information on the pdfs at the bottom of the web page or here.  If you’re still struggling, do get in touch on the…

Q: What part of a door closer is the mounting plate?

By Door Admin / 28 July 2011

A: The mounting plate, for clarification, is a thin metal plate the same size as the body of the closer.  It is good to use one for example on a uPVC door because it has lots of pre-drilled holes to enable a really firm positioning before attaching the door closer body to the plate through…

Q: Recommend a door closer suitable for fitting to a PVC Front door? Fed up with kids slamming the door every time. Door opens inwards.

By Door Admin / 21 July 2011

A: When choosing a door closer for a uPVC door, similar criteria apply to when choosing for a timber door; how wide is the door? What is its function? etc.  We suggest selecting a door closer which has an optional mounting plate and bolting through the door and the frame if possible.  Minimum specification a…

Q: What does “back check” mean on heavy duty door closers?

By Door Admin / 15 June 2011

A: “Back Check” stops the door slamming open; two examples:- on an external door in a windy location back check prevents the wind from “picking up” and opening the door (which might damage the frame at the hinges); or when there is a wall at 90° from the door back check stops damage to the…

Q: I have an Arrow door closer and it seems to have stopped working. i.e the door now slams shut. Could you call me to advise how to fix?

By Door Admin / 4 June 2011

A: Once door closers have lost hydraulic pressure, they slam the door and unfortunately can’t be fixed.  Best course of action is replace with a new door closer.

I have a fire door between my utility and garage. (W27″ X H78″ X D44mm), it is currently fitted with an undamped chain closer, which frequently results in the door slamming shut with some force…

By Door Admin / 2 June 2011

…I would like to remove the chain closer and replace it with an overhead closer with speed and latching control.  Can you recommend a suitable closer from the Geze range? At 27″ wide, your door is on the narrow side, so we’d recommend a door closer which has some adjustability on the power, because you…

Which door closers – our doors are hardwood 45mm x 840mm x 1981mm, we are not sure if Geze TS1000 will be sufficient or if we will need Geze TS1500. Please could you advise?

By Door Admin / 1 June 2011

The TS1000 door closers are perfectly adequate to cope with fire rated doors up to 900mm wide.  Geze TS1500‘s are able to cope with a wider range of door sizes, and are a little more attractive to look at.  The Eurospec F2003 is another suitable choice, as is the Briton 121.CE.

Can I Use a Floor Spring Door Closer on an External Door?

By Door Admin / 3 May 2011

Yes.  To protect the workings from water & the weather, when fitting the floor spring use sealing compound, which is available to buy on the floor spring product pages: see this link to floor springs(opens in new tab)

Winner announced of our April 1st “Most Creative Interpretation of Fire Regulations” Award

By Door Admin / 31 March 2011

Note the canny use of the fire bucket.  And the DDA compliancy of the pull handle (i.e. none).  Thank you to the fire officer who noticed this door at their kid’s school parents evening for sending us this photo. Do you have a better one?

Can a concealed door closer be fitted in the top jamb of an outward opening porch door?

By Door Admin / 21 March 2011

The only door closer which can be concealed in the top of a timber door would be the Geze Boxer, however this is not suitable to be used on an external door, so I don’t know what to suggest.  If it doesn’t need to be concealed then a normal door closer would be OK, fitted…

Q: What’s the difference between the Briton 1120B and the Geze TS2000NVBC?

By Door Admin / 20 March 2011

A: Specification-wise, they are the same; both have backcheck, adjustable power size 2-4, meet BS EN 1154 and BS EN 1634 – both CE Marked and Certifire Approved, etc.  The Geze TS2000NVBC door closers in Silver are available from us from stock.

What non-electrical door closer is suitable to stay open for a wheelchair user?

By Door Admin / 6 March 2011

There are two door closers you might consider for this application, one is the Geze TS4000 S which has delayed action.  The delayed action can be set to give up to 90 seconds delay before the door closes, which may be time to permit disabled access.  The second door closer to consider is the Geze…

I have a hotel fire door which opens 180° and obviously needs a door closer. What product can I use?

By Door Admin / 28 January 2011

The Geze TS2000 door closer will do that, as will the Geze TS4000(opens in new tab), we suggest you decide between them by the usual criteria (width of door, frequency of use, ease of power adjustment, your budget, etc)

Q: I have several door closers in my house and I want to disable 3 of them temporarily, how can I do this myself? Is there a special key for doing the job?

By Door Admin / 27 January 2011

A: The best way is to just remove the arm.

I own a pub and would like 4 door closers. Would we be okay with the light commercial closers? Do they have a suggested number of openings and closings over their lifetime?

By Door Admin / 26 January 2011

We would suggest either a Eurospec T2024(opens in new tab) door closer or the Geze TS1500(opens in new tab) which is tested to half a million cycles.  The Eurospec door closer will be more suitable for narrow doors (700-800mm aprox.), as you can set them to the lower power size 2, but both closers will…

Looking for a light weight indoor door closer.

By Door Admin / 23 January 2011

For an economical domestic door closer, we would recommend a Eurospec F2003 or Eurospec T2024 which has the advantage of being able to be set at power size 2, which is better for lighter, narrower doors.

I am trying to find a device that will stop doors slamming in a breeze – fire doors in a factory that slam closed. Do you sell dampers or an approriate soft closing device?

By Door Admin / 21 January 2011

A good quality door closer will do that job.  Please see the link to our heavy duty door closers, and I suggest you look at the Geze TS4000 or the Geze TS2000 BC (back check stops the door slamming open as well as slamming closed, and it’s a standard feature on the TS4000).